this post was submitted on 05 Oct 2024
149 points (88.2% liked)

Technology

59374 readers
3767 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related content.
  3. Be excellent to each another!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, to ask if your bot can be added please contact us.
  9. Check for duplicates before posting, duplicates may be removed

Approved Bots


founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[โ€“] [email protected] 4 points 1 month ago* (last edited 1 month ago) (1 children)

Absolutely not. At those densities, the write speed isn't high enough to trust to RAID 5 or 6, particularly on a new system with drives from the same manufacturing batch (which may fail around the same time). You'd be looking at a RAID 10 or even a variant with more than two drives per mirror. Regardless of RAID level, at least a couple should be reserved as hot spares as well.

EDIT: RAID 10 doesn't necessarily rebuild any faster than RAID 5/6, but the write speed is relevant because it determines the total time to rebuild. That determines the likelihood that another drive in the array fails (more likely during a rebuild due to added drive stress). with RAID 10, it's less likely the drive will be in the same span. Regardless, it's always worth restating that RAID is no substitute for your 3-2-1 backups.

[โ€“] [email protected] 1 points 1 month ago

Yeah I have 6 14tb drives in raid 10, I'll get 2 more if i need it.