Title reads like at ad, but this is a new way to reach energy independence. I actually have a small EcoFlow device and it’s pretty good for the price.

I hope this tech can be made available in the US soon.

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 116 points 5 months ago (68 children)

Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.

What the actual fuck?

The PowerStream has three proprietary ports: one that connects to your MC4 solar panels

Disqualified.

[–] [email protected] 12 points 5 months ago (12 children)

Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.

What the actual fuck?

What's wrong with that? That's how basically any balcony solar system works.

[–] [email protected] 14 points 5 months ago (11 children)

The cables in your walls are designed for a certain maximum current before they start to heat up. This current is limited by your breaker.

Now if you introduce a plug in solar setup your current is limited by your maximum breaker capacity + whatever your solar setup can generate.

So if I'd use the specs from the article and apply it to a normal dutch home situation: 16A breaker, + 800W at 230V, which means ~3.5A = 19.5A max. which is probably still fine for short durations.

But now some genius doesn't read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that's dangerous because it's all self installed and he doesn't know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls...

[–] [email protected] 8 points 5 months ago

But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…

Ok sure, that makes sense. This might actually be an issue.

load more comments (10 replies)
load more comments (10 replies)
load more comments (65 replies)